Tissue processing is a cornerstone of histology, transforming fresh biological samples into stable, paraffin-embedded specimens ready for microscopic examination. This intricate sequence—fixation, dehydration, clearing, infiltration, and embedding—empowers researchers, pathologists, and clinicians to study cellular and molecular structures, advancing medical research and diagnostics. However, missteps at any stage can compromise outcomes, resulting in distorted tissues, poor sections, or lost diagnostic potential. In this comprehensive guide, we explore common problems in tissue processing, their causes, and practical solutions to ensure quality results. Whether you’re a lab technician, biomedical researcher, or pathology professional, mastering these challenges is essential for success.


Common Issues in Histology Tissue Processing


Precision is critical in histology tissue processing, yet issues frequently arise from human error, improper techniques, or equipment limitations. Below, we examine three prevalent challenges—shrinkage of tissue, retained air in samples, and poor embedding or infiltration—outlining their causes and solutions to optimize your workflow.


Shrinkage of Tissue


Tissue shrinkage is a common hurdle in histology, often distorting cellular structures and hindering accurate microscopic analysis. Research suggests tissues can shrink by 20% or more by the time they’re embedded in paraffin, impacting morphology and diagnostic reliability. This problem emerges when fixatives like formalin fail to penetrate fully or are applied too briefly, typically less than 6-24 hours, leaving tissues inadequately hardened. Rapid dehydration through ethanol solutions, such as jumping from 70% to 100% too quickly, extracts water excessively, warping tissue. Excessive heat during wax infiltration, often above 60°C, further over-hardens or shrinks delicate samples, compromising quality.


Solutions for Tissue Shrinkage


  • Optimize Fixation: Use a phosphate-buffered formalin solution to stabilize tissue by cross-linking proteins, preserving its three-dimensional structure. Allow 6 to 24 hours for fixation, depending on sample size, and extend this for larger or denser tissues, using gentle agitation for even penetration to minimize distortion.


  • Control Dehydration: Follow a gradual ethanol series—70%, 90%, and 100%, with steps of 15 to 45 minutes—to remove water slowly, avoiding warping. Monitor each stage to prevent residual water, which can make tissues brittle or soft.


  • Manage Temperatures: Keep wax infiltration at 60°C or below, and regularly check embedding center hot plates and wax reservoirs to avoid overheating, ensuring reliable, high-quality sections for analysis.


Retained Air in Samples


Retained air in tissue samples creates voids, disrupts infiltration, and leads to uneven sectioning, particularly in porous or dense tissues like lung or bone. This issue often begins during fixation, where samples aren’t fully submerged in fixative, blocking reagent penetration and trapping air bubbles. Inadequate vacuum cycles in automated tissue processors, especially fluid-transfer models, fail to remove air, compromising quality. Dense or porous tissues are especially prone, as air pockets persist, hindering uniform processing and downstream analysis.


Solutions for Retained Air


Refine Fixation Setup: Submerge tissues fully in a fixative like formalin immediately after collection to ensure complete coverage. For porous samples like lung, use a vacuum chamber or gentle agitation during fixation to dislodge trapped air, preventing pockets from persisting.


Use Modern Processors: Leverage fluid-transfer tissue processors, such as the Leica Peloris™, with vacuum and pressure cycles to remove air, especially from dense tissues. Program sufficient vacuum time tailored to the sample type for optimal results.


Trim and Maintain: Trim samples to 4mm or less in thickness during dissection to facilitate fixative and reagent access, reducing air retention. Maintain equipment and train staff to spot air-related issues, like uneven staining, for smooth, high-quality sections.


Poor Embedding or Infiltration


Poor embedding or infiltration yields soft, mushy, or uneven blocks, making microtome sectioning challenging and hindering detailed analysis. This problem occurs when dehydration is incomplete, leaving residual water that blocks wax penetration, or when clearing agents like xylene fail to fully displace ethanol, compromising infiltration. Improper orientation during embedding misaligns tissues, obscuring key structures, while low-quality or impure paraffin lacks the consistency needed for firm, sectionable blocks, affecting quality.


Solutions for Better Embedding and Infiltration


Ensure Thorough Dehydration: Use a gradual ethanol series—70%, 90%, and 100%, with steps of 15 to 45 minutes—to remove all free water, checking for residual moisture before clearing to prevent soft tissues and ensure readiness.


  • Focus on Clearing: Run tissues through multiple xylene changes—20, 20, and 45 minutes—to displace ethanol fully, or use xylene-free protocols with isopropanol, adjusting wax temperatures slightly above 60°C for complete agent removal.


  • Orient and Use Quality Wax: Orient tissues carefully in molds, referencing specimen descriptions to align with research or diagnostic goals, as the plane of section is critical. Invest in premium paraffin wax with additives like styrene for hardness and elasticity, enabling thin 2 µm sections and ribbons.


  • Inspect and Train: Regularly inspect embedding centers for consistent wax quality and temperature control. Train staff to handle tissues gently and accurately, producing stable, sectionable blocks for staining and microscopy.


How to Avoid Common Tissue Processing Mistakes


Preventing mistakes in tissue processing is crucial, especially in diagnostics, where compromised samples can lead to no diagnosis and patient distress. Errors often arise from poor scheduling, inadequate fixation, or neglected reagents. To avoid these, match processing schedules to tissue type and size—avoid short runs for large, fatty samples like breast tissue or long ones for small biopsies. Fix specimens in formalin immediately after collection, adding extra time in processors if needed. Replace ethanol, xylene, and wax per strict guidelines, using tools like Leica Biosystems PELORIS for quality control. Handle tissues gently during embedding to avoid fractures, using heated forceps just warm enough to melt wax. Train staff thoroughly on techniques from dissection to embedding to reduce human error. These steps protect specimens, ensuring reliable results for research and diagnostics.

Best Practices to Ensure Quality Results


High-quality tissue processing demands sound procedures, quality materials, and meticulous care. Tailor schedules to tissue size and type, like a 6-hour run for 4mm samples, adjusting for larger or denser tissues. Invest in modern processors with vacuum/pressure cycles and fluid circulation for uniform, fast results. Refresh ethanol, clearing agents, and wax regularly, leveraging automated alerts for consistency. Use safer xylene-free options like isopropanol to maintain quality. Check embedding center hot plates and wax reservoirs to prevent heat damage. Orient tissues precisely in molds for the correct plane of section. Select premium paraffin with additives for hardness and elasticity, enabling thin, ribbon-like sections. Document processing runs, reagent changes, and equipment checks for troubleshooting. These practices deliver consistent, high-quality paraffin-embedded specimens for sectioning, staining, and analysis.


HealthSky's Liquid-Based Cytology equipment is designed to enhance diagnostic accuracy by delivering clean, well-preserved cellular samples. Its advanced processing system ensures even cell distribution on slides, supporting more precise evaluations and reducing the chances of missed abnormalities. Ideal for clinical labs, it brings consistency and clarity to routine cytological examinations.


Related Liquid-Based Cytology Products